01 / READ THE CHANGE
Control the outflow
With a prescribed supply, the controller changes outflow area to follow an illustrative cabin-altitude schedule. Relief paths act separately.


STORE MASS. STORE ENERGY.
Set the climb, change the supply and open a leak. Trace cabin pressure and temperature as a controller changes the outflow area.
Drag the turquoise handles, or focus a handle and use arrow keys. The sliders provide the same controls.
01 / READ THE CHANGE
With a prescribed supply, the controller changes outflow area to follow an illustrative cabin-altitude schedule. Relief paths act separately.
02 / READ THE CHANGE
The gas follows pV = mRT. A pressure change can come from stored mass, temperature, or both.
03 / READ THE CHANGE
The cabin stores mass and internal energy. Incoming enthalpy, outgoing enthalpy and wall heat transfer determine its thermal response.
THE SAME MODEL, CONNECTED VIEWS
B · solid turquoise A · dashed amber
| Quantity | A · saved | B · live | B − A | Unit |
|---|
A remains fixed until saved again. Export includes the model version, settings and plotted data.
Read the balance, then connect each symbol to the model. Open a symbol key for definitions and units. Long equations can be scrolled sideways.
Pressure responds to stored mass, not just to the instantaneous inlet flow.
Incoming streams carry enthalpy. The air already inside the cabin stores internal energy.
Both mass and temperature influence cabin pressure.
Rigid 60 m³ well-mixed cabin, initial sea-level pressure and 293.15 K. Aircraft climbs linearly for 900 s then levels; cabin target is min(0.25 × aircraft altitude, 2400 m). Synthetic outflow controller, 55 kPa relief onset and vacuum relief. Compressible orifice coefficient 0.7, wall UA = 25 W/K. Finite relief flow can permit pressure overshoot. No physiological limits, ECS pack cycle or aircraft-specific operating schedule.
FAA · aviation handbook library ↗Physical relations and teaching sources support the stated concepts. Generic coefficients are explicitly illustrative; they are not measured manufacturer data. Numerical verification is separate from experimental validation. Model version: applied-labs-v1.1.